Main features of capacitance & dissipation factor measuring bridge
1) Portable type, very light weight, not more than 30kg
2) Equipped with big screen (240x128mm), menu displaying with relative prompts in the right side, very simple operation, no need special training.
3) Test result can be saved or printed out; One time operation, automatic finish all the test.
4) Equipped with big capacity memory and calendar CMOS chip. Test results can be saved in time/date sequence; History records can be reviewed and printed out at any time.
5) Equipped with wiring diagram menu inside helping operator to wire correctly.
6) Equipped with earth detecting to ensure reliable earthed before being stepped up.
7) By equipped with insulation oil cup, this instrument can also test dielectric loss of insulation oil.
8) Can be suitable for testing full-sealed capacitor type voltage transformer.
9) Inside inverter and sample circuit are all digital control, output voltage is continuous adjustable
10) Equipped with multi-safety protection measures for voltage fluctuation, output short-circuit, over-voltage, over-current, over-temperature, etc.
Main parameters of capacitance & dissipation factor measuring bridge
1 |
Service conditions |
-5°C ~ 40°C |
RH<80% |
|
2 |
Principle of anti-jamming |
varying frequency |
||
3 |
Power supply |
AC220V +/-10% (no limit on frequency) |
||
4 |
HV output |
voltage |
0.5~10kV |
|
precision |
5% |
|||
Max. current |
140mA |
|||
Capacity |
1000VA |
|||
5 |
Self-exciting power |
AC 0~30V |
45Hz/55Hz |
|
Max. current |
15A |
|||
6 |
Resolution ratio |
tgδ 0.001% |
Cx: 0.1pF |
|
7 |
Precision |
Δtgδ |
+/- (reading x 1.0% + 0.040%) |
|
ΔCx |
+/- (reading x 1.0% +1.0pF) |
|||
8 |
Measuring range |
tgδ |
No limit |
|
Cx |
15pF < Cx < 100000pF |
|||
|
10kV |
Cx < 30,000pF |
||
|
5kV |
Cx < 60,000pF |
||
|
1kV |
Cx < 100,000pF |
||
For CVT |
Cx < 100,000pF |
|||
9 |
Memory size |
Can store 40 units test data |
||
10 |
Dimension |
470 x 320 x 390mm (L x W x H) |
||
11 |
Weight |
30kg |