Customization: | Available |
---|---|
After-sales Service: | Supply After-Sale Service |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1 | The OD. of steel tube | ø21~ø48mm, tolerance ≤±1.0% |
2 | The length of steel tube | 6~6.5m, bending: ≤2 mm/1000 mm. the length different of the four pipes should be less than 50mm |
3 | The Max. test pressure | 15MPa |
4 | The Precision of test pressure | the load sensor accuracy is 0.5%, and control accuracy is ±2%(Max.Testing pressure ) |
5 | Holding time of pressure | 5~30s( adjustable); |
6 | The average working efficiency | four pipes at the same time, for O.D.48 & length 6m tubing, testing pressure:10MPa, holding time 5S, the working speed is no less than 240 pieces/hour. |
7 | Testing pressure | Max. Testing pressure is 15Mpa, Axial bearing capacity is 40T |
8 | The outer surface of the tube seal | Large gap polyurethane seals; it is sealed with polyurethane hydraulic ring + bearing circular block , this kind of ring has features of steady, wear resistance and long service time(3000times) , also the open seal heads is easy to change seal rings. |
9 | Holding pressure fluctuations | Holding time 5s, fluctuations<0.3MPa Holding time 30s, fluctuations<1MPa |
10 | Space required | 10m×15m |
11 | Oil pressure | ≤15MPa |
12 | Environmental condition | Indoor, temperature: 0ºC~40ºC;humidity:-10%~100% |